Table 5 |
|||
|
Results of JEV detection by ELISA assay and RT-PCR for 60 clinical samples |
|||
|
RT-PCRb |
|||
|
|
|||
|
Positive |
Negative |
Total |
|
|
|
|||
|
ELISAa |
|||
|
Positive |
14 |
0 |
14 |
|
Negative |
6 |
40 |
46 |
|
Total |
20 |
40 |
60 |
|
|
|||
|
Compared to RT-PCR, the positive coincidence rate of ELISA: 14/(14 + 6) × 100% = 70%; the negative coincidence rate of ELISA: 40/(40 + 0) × 100% = 100%; the total coincidence rate: (14 + 40)/60 = 90%; a Antigen capture ELISA assay b Reverse transcription polymerase chain reaction |
|||
|
Mei et al. Virology Journal 2012 9:4 doi:10.1186/1743-422X-9-4 |
|||